Release notes - H3C S9500-CMW310-R1652P03
Hangzhou H3C Technologies Co., Ltd.
H3C S9500-CMW310-R1652P03
Release Notes
2010-9-27 Page 50 of 56
8.2.3 Upgrade L3PLUS BootROM
1. Reboot the L3PLUS
Login the switch through the Console port and reboot the L3PLUS board.
<H3C> reboot slot 5
It will reboot the slot. Continue? [Y/N] y
2. Download BootROM program files
Figure 2 L3PLUS structure
The serial port and network interface of a PC are connected to the serial port and
network interface of the L3PLUS board respectively. Note that the baud rate of
network interface should be set as 9600bps and that the serial port wire is the same
as that for MPU Console. Press Ctrl+B in the main menu of BootROM:
Press Ctrl+B to enter Boot Menu... 2
MAIN MENU
1. Boot from SRPU
2. Boot from FTP
3. Boot from flash
4. Load program to flash
5. Modify boot parameter
6. Write FA EEPROM