Upgrade methods
You can upgrade switch software by using one of the following methods:
Upgrade mode Object Remarks
Upgrade from the CLI
Boot ROM
System software
Reboot the switch to validate the upgrade.
This method interrupts services.
Patches
This method does not interrupt services, and fixes the
target system software only.
Upgrade from the boot
menu
Boot ROM
System software
This method can be used when the switch cannot start up.
In-Service Software
Upgrade (ISSU)
System software
This method uses an active/standby
switchover mechanism to complete upgrade
and does not interrupt services. For more
information about ISSU, see the Fundamentals
Configuration Guide in the HP A7500 Switch
Series Configuration Guides.
NOTE:
HP recommends you to upgrade software from the CLI when your switch operates normally.
To ensure that the active and standby MPUs use the same software version, upgrade them by
using the
same method.
Make sure the system software and Boot ROM are compatible. For the compatibility between the
system
software and Boot ROM, see the hardware and software compatibility matrix in the Release Notes.
You can upgrade the Boot ROM for the LPUs from the CLI only.
The command outputs in this document are for reference only.
Upgrade from the CLI
The upgrade procedure on a standalone switch is different from that on an Intelligent Resilient Framework
(IRF) fabric. This section describes the following topics:
Upgrading a standalone switch
Upgrading an IRF fabric
NOTE:
Up to two A7500 series switches can form a distributed IRF fabric. One switch is the master, and the other
is the slave.
Upgrading a standalone switch
Upgrade prerequisites
# Telnet to the switch or log in through the console port.
# Display device information.
<Sysname> display device