3Com Switch 8800 Advanced Software V5 Configuration Guide
Configuring Optional Parameters for NQA Tests 1109
# View the test results with the display nqa results command.
[Switch-nqa-admin-dlsw] display nqa results admin dlsw
NQA entry(admin admin, tag dlsw) test result:
Destination ip address: 10.2.2.2
Send operation times: 1 Receive response times: 1
Min/Max/Average Round Trip Time: 5/5/5
Square-Sum of Round Trip Time: 25
Last succeeded test time: 2006-06-07 13:25:45.1
Extend result:
Packet lost in test: 0%
Failures due to Timeout: 0
Failures due to System Busy: 0
Failures due to Disconnect: 0
Failures due to No Connection: 0
Failures due to Sequence Error: 0
Failures due to Internal Error: 0
Failures due to Other Errors: 0
Configuring Optional
Parameters for NQA
Test s
Unless otherwise specified, the following parameters are applicable to all test
types and they can be configured according to the actual conditions. Optional
parameters common to NQA are valid for all NQA tests, while those common to
an NQA test group are valid only for tests in this test group. This section covers
these topics:
■ “Configuring Optional Parameters Common to NQA” on page 1109
■ “Configuring Optional Parameters Common to an NQA Test Group” on page
1109
■ “Configuring Trap Delivery” on page 1111
Configuring Optional
Parameters Common to
NQA
Follow these steps to configure optional parameters common to NQA:
Configuring Optional
Parameters Common to
an NQA Test Group
Follow these steps to configure the optional parameters common to an NQA test
group:
To do... Use the command... Remarks
Enter system view system-view -
Configure the maximum
number of tests that the NQA
client can simultaneously
perform
nqa-agent max-requests
max-number
Optional
5 by default
To do... Use the command... Remarks
Enter system view system-view -
Enter NQA test group view nqa admin-name
operation-tag
-
Configure a descriptive string
for a test group
description text Optional
No descriptive string by
default.