3Com Switch 8800 Advanced Software V5 Configuration Guide

Displaying and Maintaining GVRP 143
n
Because GVRP is not compatible with the BPDU tunneling feature, you must
disable BPDU tunneling before enabling GVRP on a BPDU tunneling-enabled
Ethernet interface.
Because global GVRP is not compatible with Isolate-user-VLAN, make sure that
no Isolate-user-vlan has been created on the switch before enabling GVRP.
You should enable GVRP globally before enabling it on a port.
The port on which you want to enable GVRP must be a trunk port.
Configuring GARP
Timers
Follow these steps to configure GARP timers:
When configuring GARP timers, note that their values are dependent on each
other and must be a multiplier of five centiseconds. If the value range for a timer is
not desired, you may change it by tuning the value of another related timer as
shown in the following table:
Displaying and
Maintaining GVRP
To do... Use the command... Remarks
Enter system view system-view --
Configure the GARP LeaveAll
timer
garp timer leaveall
timer-value
Optional
The default is 1000
centiseconds.
Enter
Ethernet
interface
view or
port-group
view
Enter
Ethernet
interface
view
interface interface-type
interface-number
Required
Perform either of the
commands.
Depending on the view you
accessed, the subsequent
configuration takes effect on a
port or all ports in a
port-group.
Enter
port-group
view
port-group { manual
port-group-name |
aggregation agg-id }
Configure the Hold timer,
Join timer, or Leave timer
garp timer { hold | join |
leave } timer-value
Optional
The default is 10 centiseconds
for the Hold timer, 20
centiseconds for the Join
timer, and 60 centiseconds for
the Leave timer.
Tab le 16 Table 11-2 Dependencies of GARP timers
Timer Lower limit Upper limit
Hold 10 centiseconds Not greater than half of the
Join timer setting
Join Not less than two times the
Hold timer setting
Less than half of the Leave
timer setting
Leave Greater than two times the
Join timer setting
Less than the LeaveAll timer
setting
LeaveAll Greater than the Leave timer
setting
32765 centiseconds
To do... Use the command... Remarks
Display statistics about GARP display garp statistics [
interface interface-list ]
Available in any view