2 Configuration on Provider B
# Configure BPDU isolation on Ethernet 1/1/2.
<Sysname> system-view
[Sysname] interface ethernet 1/1/2
[Sysname-Ethernet1/2] port access vlan 4
[Sysname-Ethernet1/1/2] undo ntdp enable
[Sysname-Ethernet1/1/2] bpdu-tunnel dot1q enable
3 Configuration on Provider C
# Configure BPDU transparent transmission on Ethernet 1/1/3.
<Sysname> system-view
[Sysname] interface ethernet 1/1/3
[Sysname-Ethernet1/1/3] port access vlan 2
[Sysname-Ethernet1/1/3] stp disable
[Sysname-Ethernet1/1/3] bpdu-tunnel dot1q enable
[Sysname-Ethernet1/1/3] bpdu-tunnel dot1q stp
# Configure BPDU transparent transmission on Ethernet 1/4.
[Sysname-Ethernet1/1/3] quit
[Sysname] interface ethernet 1/1/4
[Sysname-Ethernet1/1/4] port access vlan 2
[Sysname-Ethernet1/1/4] stp disable
[Sysname-Ethernet1/1/4] undo ntdp enable
[Sysname-Ethernet1/1/4] bpdu-tunnel dot1q enable