Installation and Getting Started Guide for 720wl/740wl/760wl 2004-03
Hardware Installation
Site Power Requirements and Heat Dissipation
Table 2-4 shows the site power requirements and heat dissipation for the Integrated Access Manager
760wl, Access Control Server 740wl, and Access Controller 720wl.
Table 2-4. Site Power Requirements, Temperature and Heat Dissipation Parameters
Parameter Value
Power Supply Output (Watts) 56
AC Input Power (Watts) 80
Heat Dissipation (BTU/Hr.) 170
AC Input Current at 120 VAC (Amps) .88
AC Input Current at 240 VAC (Amps) .44
Operating Temperature Range,
°
C 0 to 40
Storage Temperature Range,
°
C -25 to +70
Humidity Range, non-condensing, percent 5 to 90
Installing a 700wl Series System
Note: In this section, the hardware installation instructions for the Integrated Access Manager 760wl,
Access Control Server 740wl and Access Controller 720wl are the same. Any of these is referred to as
the —chassis.“
Unpacking
Unpack the contents carefully. Save the shipping containers and all packing materials. To save storage
space, you may want to flatten the containers. Check that the following is included:
• Chassis
• Hardware and Accessories Kit
— 12-24 x 5/8 inch Phillips pan-head bolts, zinc (quantity: 4)
— 10-32 x 5/8 Phillips washer-head bolts, black (quantity: 4)
— U.S. Power Cord
— AT Null Modem (serial crossover) Cable (DB9 Female/DB9 Female)
• Documentation Kit
— Documentation CD-ROM
— Software License Agreement
— Software Release Notes
— HP ProCurve 700wl Series Quickstart Guide
— HP ProCurve Secure Access 700wl Series Installation and Getting Started Guide (this document)
If any of the above is missing, contact HP immediately and do not attempt installation.
HP ProCurve Secure Access 700wl Series Installation and Getting Started Guide 2-9










