Quick Start Guide A7000 dl 1xT1 Module (J8451A) 2006-05

61195862L1-13D, May 2006 Printed in the USA Copyright 2006 Hewlett-Packard Development Company, LP
Quick Start Guide 5990-8885
ProCurve Secure Router dl 1xT1 Module
J8451A
1XT1 MODULE COMMANDS
clock source [line* | internal]
Configures the source of the clock for the module. Use the no form of the command
to return to the default value.
line
*
Recovers clock from the T1 circuit.
internal Provides clocking using the internal oscillator.
coding [ami | b8zs*]
Configures the line coding for the T1 physical interface.
ami Configures the line coding for alternate mark inversion.
b8zs
*
Configures the line coding for bipolar eight zero
substitution.
fdl [ansi* | att | none]
Configures the format of the facility data link (FDL) channel on the T1circuit.
ansi* Configures the FDL for ANSI T1.403 standard.
att Configures the FDL for ATT TR 54016 standard.
none No FDL standard configured.
framing [d4 | esf*]
Configures the framing format of theT1 interface. This setting must match the framing
format provided by the service provider or external device. Use the no form of this
command to return to the default value.
d4 Specifies D4 superframe (SF) T1 framing.
esf* Specifies extended SF T1 framing.
lbo [long <0
*
| -7.5 | -15 | -22.5> | short <0 to 655>]
Sets the line build out (in dB or feet) for the T1 Interface. Use the lbo long command
for T1 interfaces with a cable length greater than 655 feet. Use the lbo short
command for T1 interfaces with a cable length less than 655 feet.
loopback network [line | payload]
Initiates a loopback on the interface toward the network. Use the no form of this
command to deactivate the loopback.
line Initiates a metallic loopback of the physical T1 network
interface.
payload Initiates a loopback of the T1 framer (CSU portion) of the T1
network interface.
loopback remote line [fdl | inband]
Sends a loopback code to the remote unit to initiate a line loopback. Use the no form
of this command to send a loopdown code to the remote unit to deactivate the
loopback.
fdl Uses the facility data link (FDL) to initiate a full 1.544 Mbps
physical (metallic) loopback of the signal received by the
remote unit from the network.
inband Uses the inband channel to initiate a full 1.544 Mbps
physical (metallic) loopback of the signal received by the
remote unit from the network.
loopback remote payload
Sends a loopback code to the remote unit to initiate a payload loopback. Use the no
form of this command to deactivate the loopback.
remote-alarm rai
Selects the alarm signaling type to be sent when a loss of frame is detected on the T1
receive signal. Use the no form of this command to disable all transmitted alarms.
rai* Sends a remote alarm indication (RAI) in response to a loss of
frame. Also prevents a received RAI from causing a change in
interface operational status.
remote-loopback
Configures the interface to respond to loopbacks initiated by a remote unit (or service
provider). Use the no version of this command to disable this feature.
show test-pattern
Displays the results (including error count) from active test patterns.
shutdown
Disables the interface (both physical and virtual) so that no data will be passed
through. Use the no form of this command to turn on the interface and allow it to pass
data. By default, all interfaces are disabled.
snmp trap link-status
Controls the SNMP variable, ifLinkUpDownTrapEnable (RFC2863) to enable the
interface to send SNMP traps when there is an interface status change. Use the no
form of this command to disable this trap.
tdm-group <group#> timeslot <1-24> speed [64]
Creates a group of contiguous DS0s on this interface to be used during the bind
process.
<group#> Number label (1 to 255) to identify this TDM group.
timeslot <1-24> Specifies the timeslots used in the TDM group. Enter as a single
number (representing one of the 24 T1 channel timeslots) or as
a contiguous group of channels. (For example, 1-10 specifies
the first ten channels of the T1.)
64 (Optional) Specifies a DS0 rate of 64 kbps.
test-pattern [clear | insert | ones | p511 | qrss | zeros]
Activates the built-in pattern generator and begins sending the specified test pattern.
Can be used to verify a data path when used in conjunction with an active loopback.
Use the no form of this command to cease pattern generation.
clear Clears the test pattern error count. Display the error count using
the show test-pattern command.
insert Inserts an error into currently active test pattern. Display the
injected error result using the show test-pattern command.
ones Generates a pattern of continuous ones.
p511 Generates a repeating pattern of ones and zeros.
qrss Generates a random pattern of ones and zeros.
zeros Generates a pattern of continuous zeros.
* Indicates default values.
Note
This command list is an illustration of available commands.
For complete command descriptions and default values, refer
to the SROS Command Line Interface Reference Guide
provided on your ProCurve SROS Documentation CD.