Quick Start Guide A7000 dl 8xT1/E1 Wide Module (J8463A) 2006-05
Quick Start Guide 5991-2111
ProCurve Secure Router dl 8xT1/E1 Wide Module
J8463A
61195843L1-13D, May 2006 www.procurve.com Copyright 2006 Hewlett-Packard Development Company, LP
SPECIFICATIONS
Operating Modes T1/FT1 of E1/FE1 Frame Relay, T1/FT1 or E1/FE1 PPP,
T1/FT1 or E1/FE1 HDLC, T1/FT1 or E1/FE1 Multilink Frame Relay,
T1/FT1 or E1/FE1 Multilink PPP
8xT1 Interfaces Supported Standards: AT&T TR 62411, AT&T TR 54016, ANSI T1.403,
Bellcore TR.194
Line Rate: 1.544 Mbps ±75 bps
Line Codes: AMI or B8ZS
Framing: D4 (SF) or ESF
Input Signal: 0 to -36 dB (DS1); Support for Nx64 on all T1 interfaces
(1 through 8)
Line Build-Out: 0, -7.5, -15, -22.5 dB
Connector: RJ-48C
8xE1 Interfaces Supported standards: ITU-T G.703, ITU-T G.704 (CRC-4), ITU-T G.823,
ITU-T G.797
Line Rate: 2.048 Mbps ±50 PPM
Line Codes: AMI or HDB3
Framing: FAS/NFAS with optional CRC-4
Input Signal: 0 to -30 dB (DS1) on all E1 interfaces (1 through 8)
FE1 Line Rate: Channelized timeslot
Connector: RJ-48C
Clock Source Network, internal
Diagnostics Network Loopbacks: Line, payload, remote
Test Pattern Generation and Detection: QRSS, 2
15
- 1, 511, all ones,
all zeros
Compliance FCC Part 15 Class A, EN 55022 Class A, EN 61000-3-2, EN 61000-3-3
ACIF S016, ETSI TBR 12/TBR 13, ACTA/FCC Part 68, IC CS-03
UL/CUL 60950, EN 60950, IEC 60950, AS/NZS 60950
Physical Dimensions: 14.29 cm (5.63 in) W x 21.91 cm (8.63 in) D
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Relative Humidity: Up to 95 percent, noncondensing at 30°C (86°C)
Non-Operating Temperature: -20°C to 70°C (-4°F to 158°F)
Non-Operating Relative Humidity: Up to 95 percent, noncondensing at
30°C (86°F)
Altitude: Up to 3.05 km (10,000 ft)
INSTALLATION INSTRUCTIONS
Warning
1. Remove power from the unit.
2. The 8xT1/E1 wide module is
shipped with the T1/E1 mode
switch (located on the circuit board)
set to T1 (switch set to 1). If you
require E1 functionality, using your
thumbnail, slide the switch to the
ON position as shown in the bottom
figure to the right.
3. Slide the 8xT1/E1 wide module into the wide option slot until the module is firmly
positioned against the chassis.
4. Secure the screws at both edges of the module.
5. Connect the cables to the associated device(s).
6. Complete the installation of the base unit.
7. Restore power to the unit.
Note
For safety information for the routers and all modules, please refer to the
safety and ESD precautions in the ProCurve Secure Router Installation
Guide included in your router shipment.
T1/E1 NETWORK (RJ-48C) CONNECTION PINOUT
Pin Name Description
1 R1 Receive data from the network (Ring 1)
2 T1 Receive data from the network (Tip 1)
3 — Unused
4 R Transmit data toward the network (Ring)
5 T Transmit data toward the network (Tip)
6-8 — Unused
Switch Set to E1 Mode
Switch Set to T1 Mode
For ProCurve Secure Router modules with outside plant connections, ensure
that all cables are removed from the module before installing or removing it
from the router chassis.