Quick Start Guide A7000 ISDN BRI U Backup Module (J8460A) 2006-05

61195865L1-13D, May 2006 www.procurve.com Copyright 2006 Hewlett-Packard Development Company, LP
Quick Start Guide 5991-2106
ProCurve Secure Router ISDN BRI U Backup Module
J8460A
SPECIFICATIONS
Features Clear Channel and Bonding Mode 1 call protocols
Network support for 64 kbps (1 B channel)
D-channel switch compatibility with AT&T 5ESS,
Northern Telecom DMS-100, and National ISDN-1
V.54 network loopback support
Compliance FCC Part 15 Class A, EN 55022 Class A,
EN 61000-3-2, EN 61000-3-3
ACTA/FCC Part 68, IC CS-03, UL/CUL 60950
Physical Dimensions: 6.35 cm (2.5 in) W x 9.53 cm (3.75 in) D
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Relative Humidity: Up to 95 percent, noncondensing at
30°C (86°F)
Non-Operating Temperature: -20°C to 70°C (-4°F to 158°F)
Non-Operating Relative Humidity: Up to 95 percent,
noncondensing at 30°C (86°F)
Altitude: Up to 3.05 km (10,000 ft)
Eth 0/1
Eth 0/2
dl
3
2
P/N: J8460A
US: PNBDENANJ8460
IC: 2250A-J8460
ITE
32F8
1
P/N: J8460A
US: PNBDENANJ8460
IC: 2250A-J8460
REGULATORY MODEL: RSVLC-0407C
ACCESSORY
I.T.E.
32F8
P/N: J8460A
US: PNBDENANJ8460
IC: 2250A-J8460
REGULATORY MODEL: RSVLC-0407C
ACCESSORY
I.T.E.
32F8
INSTALLATION INSTRUCTIONS
1. Remove power from the base unit.
2. If the ProCurve Secure Router interface module is already installed in
the ProCurve Secure Router chassis, remove all connected cables,
release the screws at both edges of the module faceplate, and slide
the module out of the chassis.
3. Carefully align the P1 connector on the interface module with the J1
connector on the ISDN BRI U backup module. Using only fingertip
pressure so that neither circuit board bends or flexes, ensure that the
connectors are firmly seated. Secure the backup module to the
interface module using the screws and standoff posts supplied.
4. Slide the ProCurve Secure Router interface module (with the backup
module attached) into the ProCurve Secure Router option slot until the
module is firmly seated against the chassis.
5. Secure the screws at both edges of the module.
6. Connect the cables to the associated device(s)
7. Complete installation of the base unit.
8. Restore power to the base unit.
ISDN BACKUP CONNECTION PINOUT
Pin Name Description
1-3 Unused
4 R Network-Ring
5T Network-Tip
6-8 Unused
Note
For safety information for the routers and all modules,
please refer to the safety and ESD precautions in the
ProCurve Secure Router Installation Guide included
in your router shipment.

Summary of content (2 pages)