xl Modules Installation Guide 2007-12

34
ProCurve Switch xl Modules
Troubleshooting
The network port for
which the Link LED is
blinking has
experienced a self test
or initialization failure.
During the module self test (described in item 1 above), each network port is also
tested. If the port self test fails, the individual port is not usable, but the rest of
the ports on the module, which have passed their self test, will continue to
operate normally.
If the error has occurred on a mini-GBIC that you have installed in the mini-GBIC
xl Module, make sure that it is one of the supported mini-GBICs. The ProCurve
mini-GBICs that are supported, as of the printing of this manual, are listed on
page 1. Use only the supported ProCurve mini-GBICs. If it is a supported mini-
GBIC, it may have failed. Try removing and reinstalling the mini-GBIC and it will
be tested again. If the fault indication reoccurs, the mini-GBIC is faulty and must
be replaced.
If the error has occurred on a port that contains a known valid mini-GBIC or on
a twisted-pair port or 100-FX port on one of the other modules, try removing and
reinstalling the module. If the port fault indication reoccurs, and you need to be
able to use the port, you will have to replace the module. In the mean time, all
the other ports on the module will operate normally.
The network port for
which the Link LED is
blinking has been
disabled because port
security has been
configured on the
switch and a security
violation has been
detected on the port.
For the Port Security feature, you can configure the switch so that whenever a
security violation is detected on a port, the switch will disable the port. When a
port is disabled by this feature, the port Link LED will be continuously flashed at
the fast rate of 0.8 seconds per cycle. The blinking continues until you clear the
security violation through the switch console. In the console, you can view the
identity of the connected device that committed the security violation.
Once the security violation is cleared, you must re-enable the port through the
console.
For more information on the Port Security feature, see the Management and
Configuration Guide that is on the ProCurve Web site.
Tip
Number
Problem Solution