Software Fixes
Release G.07.21 12/19/02
SNMP (PR_6006) The ifAlias OID is defaulted to “not assigned”, which may cause
network management applications such as Network Node Manager to log error messages.
[The fix is to default ifAlias to a zero-length string, as stated in the MIB.]
Release G.07.21 12/19/02
Crash (PR_5915) — The switch may crash with a message similar to: -> Software
exception at gamHwLearn.c:277 -- in 'mAdMUpCtrl' Task ID = 0x8047bca0 -> ASSERT: failed
Release G.07.20
Never released.
CDP (PR_5054) CDP multicasts are not passed when CDP is disabled on the switch.
CLI (PR_5053) Setting the telnet inactivity timeout from the CLI does not indicate a
reboot is necessary for changes to take effect.
CLI (PR_5242) Information in the command “show boot-history” is not in the order
claimed (most recent first).
Crash (PR_4986) — The switch may crash with a message similar to: -> Bus error: HW
Addr=0x00ffffff IP=0x332c4530 Task='mSess1' Task ID=0x16a62f0 fp: 0x2e2e2e29
sp:0x016a61a0 lr:0x0010f028 This crash can occur when eight transceiver modules are
installed and the command “interface all is typed in the configuration context.
Crash (PR_5236) — The switch may crash with a message similar to: -> AlphaSlaveAd-
drmgr.p 1021 this tim This crash can occur when a module is hot-swapped after downloading
new software to the switch without rebooting.
Crash (PR_5418) — The switch may crash with a message similar to: -> Software
exception at rtsock.c:459 -- in 'tNetTask', task ID = 0x1a225b0
Crash (PR_5635) — The switch may crash with a message similar to: -> Assertion failed:0,
file drvmem.c, line 167
Crash (PR_5679) — The switch may crash with a message similar to: -> Bus error: HW
Addr=0x00000000 IP=0x00000000 Task='mNSR' Task ID=0x1725148 fp: 0x0000c4b0
sp:0x012e9780 lr:0x00330674
Crash (PR_5846)WhatsUpGold telnet scan can cause switch to run out of memory and
crash with error message similar to: -> malloc_else_fatal() ran out of memory
Date/Time (PR_5264) The timezone can cause the date to wrap if the timezone is set to
a valid, but negative value (like -720) without previously configuring the switch's time. The
switch may report an invalid year (i.e. 2126).