Release Notes G.07. 53
Software Fixes
Release G.07.20
Event Log (PR_5154) — When a module fails to download, the severity code is INFO
instead of WARNING.
FFI/Port Counters (PR_5280) — FFI and port counters don't have consistent values.
FFI/Port Counters (PR_5429) — No errors are reported by the FFI or port counters when
linking at 100 HDX on a Gigabit port with a duplex mismatch.
Flow Control (PR_5102) — Setting a port “X1” in 10-HDX, then attempting to turn on flow
control returns an error similar to: “Error setting value fl for port X2”. The error should read
“X1”.
GVRP (PR_5284) — Port does not register VLAN even though advertisements are received.
Hot-swap (PR_4900) — Hot-swapping a transceiver logs a message requesting to reboot
the switch in order to enable the port, while this is not necessary.
LACP/Port Security (PR_5059) — With LACP on, the command “port-sec a1 l c action
send-alarm” fails with a message similar to “learn-mode: Inconsistent value”.
Menu (PR_5346) — The one-line help text below the password entry field, displays the
message “Enter up to 16 characters (case sensitive), or just press <Enter> to quit”. It should
read “sensitive”.
Port Configuration (PR_5444) — When interchanging 10/100-TX modules J4862A and
J4862B, the port configuration of the module originally installed in the switch is lost.
Port Counters (PR_5171) — The “Total RX Error” counter is incorrect when the port has
heavy 10HDx traffic.
Port Counters (PR_5204) — The Runt Rx counter in the detail port counter screen, does
not increment when there are fragments.
Port Counters (PR_5400) — The 64-bit counter for the highest numbered port on a given
module, does not update properly.
RADIUS (PR_4886) — Pressing the tab key gives error message similar to “BAD CHAR-
ACTER IN ttyio_line: 0x9n” when entering a username for the radius prompt.
SNMP (PR_5349) — The switch does not send SNMP packets larger than 484 bytes.
SNTP/TIMEP (PR_5018) — SNTP still runs when timep is enabled.
System Information (PR_5169) — Up Time displayed is not correct.
TFTP (PR_5034) — Trying to TFTP a config onto the switch causes the switch to not
complete its reload process. The switch hangs and does not come up.
Web-Browser Interface (PR_4495) — Administrator password can be used in combina-
tion with the operator username.