Release Notes G.07. 53

Software Fixes
Release G.03.13 12/13/02
CLI (PR_3521) The response to an incomplete trunk configuration command did not
produce the proper message “Incomplete input: Trunk.
CLI (PR_3750) — The crash history is lost after the “reload” command is performed from
the CLI.
Crash (PR_3736) — Switch may crash with a message similar to: ->Software exception at
bcm56xxDmaPoll.c:342--in 'sal_dpc_hi' ->Msg loss detected
Crash/Bus Error (VARIOUS) — A Get request of a specific long OID can result in a bus
error, an agent hang, or a switch crash with a message similar to: -> Software_exception at
svc_misc.s:379 -- in mCdpCtrl malloc_else_fatal() ran out of memory This crash has been
associated with the CERT SNMPv1 "Req-app" test suite.
Flow Control (PR_3026) — Changing Flow Control setting on a port is not reflected in
Auto-negotiation's advertised capability.
Menu/Web-Browser Interface (PR_3534) — Display of mirror port configuration is
inconsistent between menu and WEB interface.
Port Configuration (PR_3028) — Changing a port setting from one Auto mode to another
may not be reflected in Auto-negotiation's advertised capability without a switch reset, or
module hot-swap.
Port Monitoring (PR_3596) Port monitoring does not work correctly after a TFTP
transfer of the configuration from the switch to the server and then back to the switch.
Stack Management (PR_3493) — Master switch was not properly making security checks
when passing information along to a member switch.
TFTP (PR_3518) — Menu and browser displays of switch configuration are not accurate
after a TFTP transfer of the switch config file to the switch. Only occurs when a port is
configured for network monitoring.
Web-Browser Interface (PR_1483) — User could input an invalid MAC address, i.e.
multicast or broadcast address, in the security policy field.
Web-Browser Interface (PR_3113) — Incorrect font size used in VLAN configuration
screen.
Web-Browser Interface (PR_3519) — Web display of port utility window did not display
port H24.
Release G.03.13 12/13/02
Inter-module Communication Problems (PR_3856) — When the switch's MAC address
learning function detects the same MAC address on two different modules within a small
interval of time (this could happen if two end nodes have the same MAC address or if there
27