Installation and Reference Guide HP AdvanceStack 100Base-THub-12TX, Hub-12TXM, and Switch Modules 1997-06
Pin Assignments B-1
Appendix B: Pin Assignments
RJ-45 Port
Hub Cable
Figure B.1
RJ-45 Connector
(on the Hub Side)
RJ-45 station ports (MDI-X) can be attached to any devices that
use a standard network interface (e.g., a workstation, server or
router). RJ-45 cascade ports (MDI) can be cascaded to a
station port on similar networking devices (e.g., another switch
or router). Use unshielded twisted-pair (UTP) or shielded
twisted-pair (STP) cable for RJ-45 connections: 100W
Category 3, 4 or 5 cable for 10 Mbit/s connections or 100W
Category 5 cable for 100 Mbit/s connections. Also be sure that
the length of any twisted-pair connection does not exceed 100
meters.
Pin
Assignment for MDI-X
Station Ports 1 ~ 12
Assignment for
Cascade Port 12MDI
1 Receive Data + Transmit Data +
2 Receive Data - Transmit Data -
3 Transmit Data + Receive Data +
6 Transmit Data - Receive Data -
4,5,7,8 Not Used Not Used
Table B.1 RJ-45 Pin Assignments
Schematics for both straight and crossover twisted-pair cable
are shown below.
Straight-Through Crossover
(Hub) (Adapter) (Hub) (Hub)
1 1 1
1
2 2 2
2
3 3 3 3
6 6 6 6