Switch 7700 Command reference Guide, v2.0

Table Of Contents
Logging in Commands 31
Use the undo header { shell | incoming | login } command to delete the
specified header.
Example
To configure a header to display after connection using the control character
method, enter the following.
[SW7700]header shell %
Enter TEXT message. End with the character '%'.
SHELL : Hello! Welcome %
The header text displays on the terminal when a user next logs in. To test this, quit
from the session, and press Enter to restart.
[SW7700]quit
<SW7700>quit
Press ENTER to get started
SHELL : Hello! Welcome
<SW7700>
history-command
max-size
Syntax
history-command max-size value
undo history-command max-size
View
User interface view
Parameter
value: Enter the number of previously entered commands that you want the
Switch to save.
Description
Use the command history-command max-size to specify the amount of
previously entered commands that you want the Switch to save. Enter any
value between 0 and 256. The default is 10, that is, the 10 most recently
entered commands are saved.
Use the undo history-command max-size command to restore the default
value.
To display the most recently-entered commands, up to the specified maximum,
use the command
display history-command.
Example
To set the history buffer to 20, that is to save the 20 most recently-entered
commands, enter the following:
[SW7700]history-command max-size 20
idle-timeout Syntax
idle-timeout minutes [ seconds ]
undo idle-timeout