Switch 7700 Command reference Guide, v2.0

Table Of Contents
484 CHAPTER 11: USING SYSTEM MANAGEMENT COMMANDS
Related command: rmon event.
Example
Show the RMON event.
<SW7700>display rmon event
Event table 1 is VALID, and owned by 3COM.
Description: none.
Event firing causes log ,last fired at 0.
display rmon eventlog Syntax
display rmon eventlog [ event-number ]
View
All views
Parameter
event-number: Entry index of event table.
Description
Using the display rmon eventlog command, you can display RMON event log.
The display includes description about event index in event table, description to
the event, and occurrence time of the latest event (counted on system
initiate/boot time in centisecond).
Example
Show event log of RMON.
<SW7700>display rmon eventlog 1
Event table 1 is VALID, and owned by 3Com.
Description: none.
Event firing causes log-and-trap ,last fired at 102300.
Event 1 generates eventLog 1.
Description: The 1.3.6.1.2.1.16.1.1.1.4.8 defined in alarm table 2,
less than 200 with alarm value 0. Alarm sample type is delta.
loged at 21300.
Event 1 generates eventLog 2.
Description: The 1.3.6.1.2.1.16.1.1.1.4.8 defined in alarm table 2,
uprise 1000 with alarm value 10443. Alarm sample type is delta.
loged at 102300.
Tab le 40 Output description of the display rmon event command
Field Description
Event table 1 Index 1 in event table
VALID The entry corresponding to the index is valid
3COM Owner
Description Event description
Event firing causes log Log triggered by event
last fired at 0 Occurrence time of the latest event (counted since system
initiate/boot time in centisecond)