HP 7500/7900 Switch Series - HP 7500-CMW520-R6703 Release Notes

9
LSD071172
Symptom: Portal authentication is unavailable when the MPU modifies portal authentication
settings.
Condition: This symptom might occur if portal authentication settings are modified when CPU usage
is high.
LSD070985
Symptom: BGP route calculation occupies too many CPU resources during link switchover or
fallback.
Condition: This symptom might occur if many BGP route reflectors exist.
LSD071729
Symptom: The subordinate device in an IRF fabric reboots.
Condition: This symptom might occur if undo vsi is executed when the state of the peer is changing.
LSD071750
Symptom: IMC cannot show the panel of the switch.
Condition: This symptom occurs when IMC accesses the switch.
LSD071724
Symptom: Track fails to work when PBR needs to perform a nexthop failover.
Condition: This symptom might occur if the following conditions exist:
PBR has more than two nodes.
The two PBR nodes specify two next hops.
Track is used to trigger a nexthop failover.
Track fails to work when PBR needs to perform a nexthop failover.
LSD072125
Symptom: In an IRF fabric, a card that has IRF physical ports continually reboots, which causes
continual reboots of the chassis that hosts the card.
Condition: This symptom might occur if an unsupported switch-mode is configured for the card, for
example, because of manual configuration file editing or member ID renumbering.
LSD072333
Symptom: The IRF fabric splits even though the IRF links are up.
Condition: After an MPU exception occurs on an IRF member chassis, this symptom might occur if
the chassis cannot complete an active/standby switchover before IRF handshaking times out.
LSD072193
Symptom: In an IRF fabric, only the global active MPU starts up normally, and all other MPUs stay
in STM init state.
Condition: This symptom might occur if the IRF fabric is rebooted while the IRF links are flapping.