HP 7500/7900 Switch Series - HP 7500-CMW520-R6703 Release Notes
30
NOTE:
Make sure that the upgrade files exist in the root directory of the storage medium of the active and standby
MPUs of the IRF fabric.
Perform the following tasks as needed:
Upgrade Boot ROM
Upgrade system software
Install patches
1. Upgrade Boot ROM
# Upgrade the Boot ROM program of the active MPU of the IRF fabric.
<Sysname> bootrom update file flash:/newboot.btw chassis 1 slot 0
This command will update bootrom file on t he specified board(s),
Continue? [Y/N]:y
Now updating bootrom, please wait...
Start accessing bootflash chip...
Bootrom update succeeded in chassis 1 slot 0.
# Upgrade the Boot ROM program of each standby MPU of the IRF fabric.
On the standby MPU in slot 1 of member device 1
<Sysname> bootrom update file chassis1#slot1#flash:/newboot.btw chassis 1 slot 1
This command will update bootrom file on the specified board(s), Continue? [Y/N]:y
Now updating bootrom, please wait...
Start accessing bootflash chip...
Bootrom update succeeded in chassis 1 slot 1.
On the standby MPU in slot 0 of member device 2
<Sysname> bootrom update file chassis2#slot0#flash:/newboot.btw chassis 2 slot 0
This command will update bootrom file on the specified board(s ), Continue? [Y/N]:y
Now updating bootrom, please wait...
Start accessing bootflash chip...
Bootrom update succeeded in chassis 2 slot 0.
On the standby MPU in slot 1 of member device 2
<Sysname> bootrom update file chassis2#slot1#flash:/newboot.btw chassis 2 slot 1
This command will update bootrom file on the specified board(s), Continue? [Y/N]:y
Now updating bootrom, please wait...
Start accessing bootflash chip...
Bootrom update succeeded in chassis 2 slot 1.
# Reboot the IRF fabric to validate the upgrade.
<Sysname> reboot
Start to check configuration with next startup configuration file, please wait.
........DONE!
This command will reboot the device. Continue? [Y/N]:y