HP 7500/E7900 Switches and Fabric Modules - 7500-CMW520-R6708 Release Notes
13
LSD070621
Symptom: OSPF calculation occupies too many CPU resources when flooding occurs because of
LSA aging.
Condition: This symptom might occur in an OSPF network where large numbers of routes and OSPF
neighbors exist and NSR is enabled.
LSD070593
Symptom: The private MIB OID value is 25506(HP), and it should be replaced with 6296(Dasan).
Condition: Read the MIB tree of a Dasan device.
Resolved problems in R6701
LSD68827
Symptom: MPLS works abnormally.
Condition: After a switch reboots, IPC communication may fail, resulting in failure of assigning
MPLS forwarding entries to cards.
LSD69305
Symptom: An anomaly occurs to the switch.
Condition: Configure multiple DHCP Options on the DHCP server. Enable debugging on a switch,
and then use the switch as the DHCP client to request configuration information from the DHCP
server.
LSD69168
Symptom: The switch may reboot abnormally.
Condition: Disable MPLS LDP on an interface.
LSD68974
Symptom: The cross-chassis forwarding packets will be lost.
Condition: An IRF system with SRPD fabric on 7506/7503 chassis.
Resolved problems in R6635
LSD66053
Symptom: The memory leaks.
Condition: When Portal is enable and HTTP attack occurs.
LSD66086
Symptom: Run display diagnosis on slave-super-engine, it can’t return.
Condition: Run display diagnosis on slave-super-engine.
LSD64527
Symptom: The LDP session is not stable.
Condition: When the device is linked with other company’s device with VLL.