HP 7500/E7900 Switches and Fabric Modules - 7500-CMW520-R6708 Release Notes

34
Upgrade from the boot menu
You can upgrade the Boot ROM program and system software image for the MPUs from the boot menu.
Upgrading Boot ROM from the boot menu
Upgrading system software from the boot menu
CAUTION:
You cannot simultaneously upgrade the active and standby MPUs from the boot menu. To ensure that the
active and standby MPUs use the same software version, upgrade them in turn.
Upgrading Boot ROM from the boot menu
Upgrade the Boot ROM program from the boot menu by using one of the following methods:
Using TFTP through the management Ethernet port
Using FTP through the management Ethernet port
Using Xmodem through the console port
Using an upgrade file on the switch
Using TFTP through the management Ethernet port
Step1 Connect the management Ethernet port of the switch to the PC that stores the target .app file (the IP
address of the PC is required), and connect the console port of the switch to the same or another PC.
Step2 Run the TFTP server program on the PC connected to the management Ethernet port and specify the file
storage directory.
Step3 Run the terminal emulation program on the PC connected to the console port. Start the switch, enter the
boot menu (see Error! Reference source not found. for more information), and press Ctrl+U when
you see "Enter your choice(0-5):" to enter the Boot ROM update menu.
BootRom update menu:
1. Set TFTP protocol parameters
2. Set FTP protocol parameters
3. Set XMODEM protocol parameters
4. Update through file in device
0. Return to boot menu
Enter your choice(0-4):
Step4 In the Boot ROM update menu, type 1 to set the TFTP parameters.
BootRom update menu:
1. Set TFTP protocol parameters
2. Set FTP protocol parameters
3. Set XMODEM protocol parameters
4. Update through file in device
0. Return to boot menu
Enter your choice(0-4):1