Installation Guide for cl Modules 2006-03

5
Installing the Modules
Installing the Modules
You can install any of the modules into any of the ProCurve cl Switches that
have a compatible module slot. As of this printing, those are the
ProCurve Series 3400cl Switch:
3400cl-24G (J4905A)
3400cl-48G (J4906A)
ProCurve Series 6400cl Switch:
6400cl-6XG CX4 (J8433A)
6410cl-6XG X2 (J8474A)
“Hot Swap”
Notes
The transceivers can be “hot swapped”. That is, they can be installed or
removed after the Media Flex cl Module is installed in the switch and the
module is receiving power.
The expansion cl module itself is not “hot-swappable” or “hot pluggable.” You
cannot insert or remove a module while the switch is powered on without
interrupting the operation of the rest of the switch ports. If you install or
remove an expansion cl module with the switch powered on, a reboot will
occur.
You can install the modules into the switch either with the switch powered on
or off. The following procedures assume the switch is powered off.
1. Install a module (see page 7).
2. If you are using the Media Flex cl Module, install the transceivers in the
module. You can install the transceivers before or after installing that
module into the switch (see page 8).
3. Verify the modules are installed correctly (see page 9).
4. Connect the network cabling (see page 10).
5. Verify the network connections are working properly (see page 12).