Avaya Aura Session Border Controller powered by Acme Packet Installation and Getting Started Guide 2010-09
2-10
Hardware Installation
Install the HP Extended Services zl Module
To install the module into a switch, the switch can be powered on or off. The
following procedure assumes the switch is powered on.
Installation Steps
1. Use a Torx T-10 or flat-bladed screwdriver to unscrew the screws in the
cover plates over slots A and C, where you will install an Extended
Services zl Module. Note that the module occupies two slots. Remove the
cover plates from both slots and store them for possible future use.
2. Hold the module by its bulkhead, taking care not to touch the metal
connectors or components on the board.
3. Open the extractor handles.
4. Insert the module, aligning with the guides in the slots, and slide it into
the slots until it is fully inserted.
5. Once the module is fully inserted, use the extractor handles to seat it
completely.
■ For safe operation, proper switch cooling, and reduction of electromag-
netic emissions, ensure that a slot cover is installed on any unused
module slot. For safety, no more than one slot should be uncovered at
a time, even temporarily, when the switch is powered on.
■ Check the temperature specifications for the module; different modules
have different temperature requirements.
Installation Precautions(Continued)