Field Replaceable Units (FRU) Guide, HP Advanced and Extended Services zl Modules 2011-03
9
Hardware Replacement Procedures
3. Slide out the old compact flash by applying slight pressure to the top of
the compact flash.
4. Position the new compact flash properly and slide it in being careful not
to bend any connector pins.
3. 4.
Figure 5b. Steps for Replacing the Module’s Compact Flash
5. If applicable, remove the cover from the slot where the module will be
re-installed. Re-install the module into the switch.
6. Use an equal amount of pressure and push both extractor handles closed
to completely seat the module.
7. Tighten the retaining screws.
8. Now please refer to “Restoring Product Operation” on page 12 for the
next steps to restore full software operation of your AllianceONE zl
Module product. Look for the section that applies to your product, and
“After CF Replacement”.
Replacing the Module
Your replacement ONE ES Module will not have an HDD or a CF installed in
it. Remove those components from the faulty ONE ES Module and install them
into the replacement module.
It is highly recommended that the faulty module be shutdown before replacing
it. The module maybe shutdown using the shutdown button on the front panel
of the module or using the following CLI command:
hostswitch# services <slot-id> shutdown