Field Replaceable Units (FRU) Guide, HP Advanced and Extended Services zl Modules 2011-03

10
Hardware Replacement Procedures
It is possible to “hot-swap” one module for another of the same type; that is,
replace one module with another while the switch is still powered on, without
interrupting the operation of the rest of the switch ports. If the modules are
not the same type, the switch may have to be reconfigured. If you use the
shutdown command first, the switch will not have to be reset.
Caution A 5-second delay is mandatory between removing a module, and either re-
installing it, or replacing it with another.
To replace the faulty AllianceONE zl Module with a replacement one, use the
following procedure:
1. Unscrew the retaining screws enough to disconnect them from the
threaded holes in the switch.
2. Using the extractor handles pull the module out from the slot.
3. Remove the HDD from the faulty module and install it in the replacement
module. The procedure is essentially the same as described under
“Replacing the HDD” on page 6 except that you move the HDD from one
module to another.
4. Remove the CF from the faulty module and install it in the replacement
module. The procedure is essentially the same as described under
“Replacing the Compact Flash” on page 8 except that you move the CF
from one module to another.
5. If the module you are replacing is an SBM AllianceONE zl Module
product, you will also have to remove the PCIe cards from the faulty
module and install them in the replacement module. Important: Make
sure that you place the PCIe cards in the same slots in the replacement
module as they were located in the faulty module.
6. Install the replacement module into the switch slots where the faulty
module was previously located, as described in the previous procedures.
Caution For proper cooling and reduction of electromagnetic emissions, ensure that
a slot cover is installed on any unused slot. In an operational chassis, an
unused slot should be covered if it is not used for more than 2 minutes.
7. Now please refer to “Restoring Product Operation” on page 12 for the
next steps to restore full software operation of your AllianceONE zl
Module product. Look for the section that applies to your product, and
“After zl Module Replacement”.