Field Replaceable Units (FRU) Guide, HP Advanced and Extended Services zl Modules 2011-03

17
Restoring Product Operation
same arrangement. If the cards are replaced in the incorrect slots, then
the gateway will not start and you will be required to rerun the PSTN Setup
Wizard to redo the module configuration.
SBC AllianceONE zl Module
Follow these procedures to restore your SBC AllianceONE zl Module product
to full operation if you have had to replace the HDD, the CF, or the ONE ES
Module.
After HDD Replacement
After replacing the fault HDD into your zl Module and reinstalling the module
into the switch, the module should automatically boot into the product OS.
You can confirm that by entering this command from the switch prompt:
hostswitch# services <slot-ID> 1
where: <slot-ID> is the letter identifier of the switch slot in which the
module is installed. The index number 1 (one) is the context identifier for
the module, not the application running on the module.
If the module has booted into the product OS, the prompt will include the
characters :App)# at the end.
If the module has booted into the Service OS, the prompt will include the
characters :SvcOS)# at the end.
1. Confirm that the HDD installation is correct by accessing the Avaya Aura
System Platform console:
a. From your web browser running on a PC that is in the same subnet
as the SBC module, access the System Platform browser interface by
entering the URL https://192.168.1.50/webconsole. If you have changed
the webconsole (cdom) IP address from the default, then use that new
IP address in the webconsole URL. You should see a screen similar to
the following: