Getting Started Guide for Wireless EDGE Services xl Modules 2007-07

16
Getting Started
Note: The User Name is a read-only SNMP v3 username of operator or
manager. Operator typically has an Access Control of read-only and Manager
typically has an Access Control of read/write. The password is subject to the
same rules of SNMP v.3, which requires a password length of 8 characters or
more.
Step 5 - Set up Country Code and other wireless network
administrative data.
In this step, the following the Module is set up with the Country Code and
other administrative data.
1. From the Navigation Pane, select Network Setup
2. Select appropriate Country Code.
3. Enter data for the System Name, Location, and Contact.
4. Select Apply to save the settings for this session.
5. Select Save to save the settings in a non-volatile memory in the Module.
The screen below shows these entries.
Note: The APPLY changes are made to the current configuration only, and if
the module is reloaded these changes are lost. To keep the changes for re-use
they must be saved using the SAVE button.
This Network screen also provides the administrator with additional informa-
tion, as noted below. These definitions are also available on the Help menu.
System: