HP Advanced Services v2 zl Module Installation Guide

Installation precautions
Static electricity can severely damage the electronic components on the module. When handling
and installing the module, follow these procedures to avoid damage from static electricity:
Handle the module by its bulkhead or edges and avoid touching the components and
the circuitry on the board.
When installing the module, equalize any static charge difference between your body
and the switch by wearing a grounding wrist strap and attaching it to the metal body of
the switch, or by frequently touching the metal body of the switch.
For safe operation, proper switch cooling, and reduction of electromagnetic emissions, ensure
that a slot cover is installed on any unused module slot. For safety, no more than one slot
should be uncovered at a time when the switch is powered on.
The temperature specifications of the module must be followed.
Environmental specifications
Non-Operating
-40°C to 70°C (-40°F to 158°F)
Operating
0°C to 45°C (32°F to 113°F)
Temperature
15% to 90% at 65°C (149°F)
2
15% to 95% at 40°C (104°F)
1
Relative humidity (non-condensing)
4.6 km (15,000 ft)3.0 km (10,000 ft)Maximum altitude
1
The HDD (J9857A) has a maximum operational wet bulb temperature of 28°C (82°F).
2
The HDD (J9857A) has a maximum non-operational wet bulb temperature of 28°C (82°F).
Other documentation
For full information on configuring and managing the module, see the HP Advanced Services v2
zl Modules Configuration Guide.
Installation precautions 7