HP Advanced Services zl Module with Citrix XenServer™ Platform Quick StartGuide
1-5
Hardware Installation
Environmental Specifications
Error conditions indicated by the module LEDs are described in Appendix C
of the Installation and Getting Started Guide available on the web:
www.hp.com/networking/support.
Environmental Specifications
Table 1-2. Environmental Specifications
Table 1-3. Maximum Advanced Services Modules
*Notes on the Advanced Services Module operating temperature:
1. Operate at 50°C
a. The Advanced Services Module can operate in an HP E5406 zl or
E5412 zl switch can operate at up to 50°C if you install all Advanced
Services Modules on the left side of the chassis. When facing the front,
or port side, of the switch, the left side slots are A, C, E, G, I, and K.
See Figure 1-3 on page 1-6.
b. If you want an E5406 zl switch to operate at up to 50°C, the switch
supports a maximum of three Advanced Services Modules (because
the switch has three slots on the left side).
2. Operate at 45°C
a. The 45°C limit applies to the E5406 zl and E5412 zl switches if any
Advanced Services Modules are installed on the chassis’ right side,
which includes module slots B, D, F, H, J, and L. See Figure 1-3 on
page 1-6.
Temperature Operating*
0°C to 45°C (32°F to 113°F)
Non-Operating
-10°C to 65°C (-10°F to 149°F)
Relative humidity
(non-condensing)
15% to 90% at 40°C (104°F) 15% to 90% at 65°C (149°F)
Maximum altitude 3.0 km (10,000 ft) 4.6 km (15,000 ft)
Switch Model Maximum Advanced Services Modules
E5406 zl 4
E5412 zl 4
E8206 zl 2
E8212 zl 4