HP ProCurve Network Immunity Manager with a Third-Party IDS/IPS
Step 2: Detect Threats
d. Optionally, type information in the Sensor Contact and Sensor Location fields.
e. Accept the default Sensor Agent Port of 161, unless you are using a different port
in PCM+.
f. Accept the default Sensor Agent Protocol of UDP, unless you are using TCP in PCM+.
g. Click Apply.
6. In the navigation bar, select SNMP > Traps Configuration.
7. Configure SNMP trap settings.
a. Make sure that the Enable SNMP Traps check box is selected.
b. Under SNMP Traps, select which error events will be forwarded to PCM+. ProCurve
recommends that you select all three check boxes:
–Fatal
–Error
– Warning
c. Make sure that the Enable detailed traps for alerts check box is selected. This will provide
useful detail to PCM+/NIM.
d. Type the Default Trap Community String. This should be the same as the read-only
community name you configured in step 5.
Figure 3-35. Configuring SNMP
e. In the right pane, click Add.
f. In the window that is displayed, type:
– Management station’s IP address
– UDP port on which the management station sends traps (use 162 unless PCM+ is
using a different port number)
– Trap community string (same as the read-only community name: public)