32
NOTE:
• The size of an application is often over 10 MB.
Even if the baud rate is set to 115200 bps,
it usually takes about 30 minutes to upgrade the application through the serial
interface. Therefore, you are recommended to upgrade applications through an
Ethernet interface.
• If you want the SecBlade card to use the downloaded file, you need to specify the file
for the next boot. For related information, refer to “Specifying ” on page 17.
Upgrading the BootWare program
Select 7 on the main menu (refer to “Main ” on page 22) to enter the BootWare operation
submenu, where you can perform all operations related to the BootWare program. For
details about the BootWare operation submenu, refer to “BootWare operation ” on page
26.
The following example shows how to upgrade the entire BootWare program:
Step1 Modify the baud rate of the serial interface to improve the upgrade speed (for details,
refer to “Modifying serial interface ” on page 28) and then select 3 on the BootWare
operation submenu. The following information is displayed:
===========<BOOTWARE OPERATION SERIAL SUB-MENU>==============
| <1> Update Full BootWare |
| <2> Update Extended BootWare |
| <3> Update Basic BootWare |
| <4> Modify Serial Interface Parameter |
| <0> Exit To Main Menu |
=============================================================
Enter your choice(0-4):
Step2 Select 1. The following information is displayed:
Waiting ...CCCCCCCCCCCCCCCCCCCCCCCCC...
Step3 Select Transfer > Send file in the HyperTerminal window. The following dialog box appears:
Figure 12 Send File dialog box
Step4 Click Browse… to select the application file to be downloaded, and select Xmodem from
the Protocol dropdown list. Then click Send and the following dialog box appears: