HP Switch Services Modules - HP SECBLADEII-CMW520-F3171P05 Release Notes

HP SECBLADEII-CMW520-F3171P05
Release Notes
Hewlett-Packard Development Company, L.P.
39
Figure 13 Sending file dialog box
After the file is downloaded, the following information is displayed on the configuration
terminal:
Download successfully!
10129792 bytes downloaded!
NOTE:
The size of an application is often over 10 MB. Even if the baud rate is
set to 115200 bps,
it usually takes about 30 minutes to upgrade the application through the serial
interface. Therefore, you are recommended to upgrade applications through an
Ethernet interface.
If you want the SecBlade card to use the downloaded file, you need to specify the file
for the next boot. For related information, see Specifying files on page 23.
Upgrading the BootWare program
Select 7 on the main menu (see Main menu on page 29) to enter the BootWare
operation submenu, where you can perform all operations related to the BootWare
program. For details about the BootWare operation submenu, see BootWare operation
submenu on page 33.
The following example shows how to upgrade the entire BootWare program:
Step1 Modify the baud rate of the serial interface to improve the upgrade speed (for details, see
Modifying serial interface parameters on page 35) and then select 3 on the BootWare
operation submenu. The following information is displayed:
===========<BOOTWARE OPERATION SERIAL SUB-MENU>==============
| <1> Update Full BootWare |
| <2> Update Extended BootWare |