24
|<6> Skip Current System Configuration |
|<7> BootWare Operation Menu |
|<8> Clear Super Password |
|<9> Storage Device Operation |
|<0> Reboot |
=============================================================================
Enter your choice(0-9):
Table 10 BootWare menu options
Item
Description
<1> Boot System
Boot the system software image.
<2> Enter Serial SubMenu
Access the Serial submenu (see Table 13 ) for upgrading
system software through the console port or changing the
serial port settings.
<3> Enter Ethernet SubMenu
Access the Ethernet submenu (see Table 11 ) for upgrading
system software through an Ethernet port or changing
Ethernet settings.
<4> File Control
Access the File Control submenu (see Table 14 ) to retrieve
and manage the files stored on the firewall card.
<5> Modify BootW are Password
Modify the BootWare password.
<6> Skip Current System
Configuration
Start the firewall card with the factory default
configuration. This is a one-time operation and does not
take effect at the next reboot. You use this option when
you forget the console login password.
<7> BootW are Operation Menu
Access the BootW are Operation menu for backing up,
restoring, or upgrading BootW are.
<8> Clear Super Password
Clear all super passwords used for switching to higher user
privilege levels.
By default, no super password is required for switching to a
higher user privilege level.
<9> Storage Device Operation
Access the Storage Device Operation menu to manage
storage devices.
<0> Reboot
Restart the firewall card.
Using TFTP/FTP to upgrade software through an Ethernet
port
1. Enter 3 in the BootWare menu to access the Ethernet submenu.
==========================<Enter Ethernet SubMenu>==========================
|Note:the operating device is cfa0 |
|<1> Download Application Program To SDRAM And Run |
|<2> Update Main Application File |
|<3> Update Backup Application File |
|<4> Update Secure Application File |
|<5> Modify Ethernet Parameter |
|<0> Exit To Main Menu |
|<Ensure The Parameter Be Modified Before Downloading!> |