Handling software upgrade failures
If a software upgrade fails, the system runs the old software version. To handle a software
failure:
1. Check the physical ports for a loose or incorrect connection, and verify the LEDs are
correctly reflecting the port status.
2. If you are using the console port for file transfer, check the HyperTerminal settings
(including the baud rate and data bits) for any wrong setting.
3. Check the file transfer settings:
If XMODEM is used, you must set the same baud rate for the terminal as for the
console port.
If TFTP is used, you must enter the same server IP addresses, file name, and working
directory as set on the TFTP server.
If FTP is used, you must enter the same FTP server IP address, source file name,
working directory, and FTP username and password as set on the FTP server.
4. Check the FTP or TFTP server for any incorrect setting.
5. Check that the CF card has sufficient space for the upgrade file.
6. If the message "Something is wrong with the file" appears, check the file for file
corruption.