HP VPN Firewall Appliances Getting Started Command Reference

30
Views
User interface view
Default command level
2: System level
Parameters
speed-value: Transmission rate in bps. The transmission rates available for asynchronous serial interfaces
include: 300 bps, 600 bps, 1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 bps, 38400 bps, 57600
bps, and 115200 bps. The transmission rate varies with devices and configuration environments.
Usage guidelines
This command is only applicable to console and AUX user interfaces.
The configuration terminal and the device must be configured with the same transmission rate to
communicate.
Examples
# Set the transmission rate on the console user interface to 19200 bps.
<Sysname> system-view
[Sysname] user-interface console 0
[Sysname-ui-console0] speed 19200
stopbits
Use stopbits to specify the number of stop bits for a character.
Use undo stopbits to restore the default.
Syntax
stopbits { 1 | 1.5 | 2 }
undo stopbits
Default
One stop bit is used.
Views
User interface view
Default command level
2: System level
Parameters
1: Uses one stop bit.
1.5: Uses one and a half stop bits.
2: Uses two stop bits.
Usage guidelines
This command is only applicable to the console user interface.
The configuration terminal and the device must be configured to use the same number of stop bits to
communicate.