HP VPN Firewall Appliances Getting Started Command Reference
45
Default
ACSEI server is disabled.
Views
System view
Default command level
2: System level
Examples
# Enable ACSEI server.
<Sysname> system-view
[Sysname] acsei server enable
acsei timer clock-sync
Use acsei timer clock-sync to set the synchronization timer that is used for clock synchronization from the
ACSEI server to the ACSEI client.
Use undo acsei timer clock-sync to restore the default.
Syntax
acsei timer clock-sync minutes
undo acsei timer clock-sync
Default
The clock synchronization timer is set to 5 minutes.
Views
ACSEI server view
Default command level
2: System level
Parameters
minutes: Specifies the synchronization time in minutes, in the range of 0 to 1440. Setting it to 0 disables
the clock synchronization from the ACSEI server to the ACSEI client.
Examples
# Set the clock synchronization timer to 20 minutes.
<Sysname> system-view
[Sysname] acsei server
[Sysname-acsei-server] acsei timer clock-sync 20
acsei timer monitor
Use acsei timer monitor to set the monitoring timer for the ACSEI server to use for ACSEI client
monitoring.
Use undo acsei timer monitor to restore the default.