HP VPN Firewall Appliances Getting Started Command Reference
55
Usage guidelines
To verify the setting, use the display clock command.
The timestamps in system messages are adjusted in reference to the time zone and daylight saving
schedule.
Examples
# Set the local time zone to add five hours to UTC time.
<Sysname> system-view
[Sysname] clock timezone z5 add 5
Related commands
• clock datetime
• clock summer-time one-off
• clock summer-time repeating
• display clock
configure-user count
Use configure-user count to configure the maximum number of users allowed to enter system view at the
same time.
Use undo configure-user count to restore the default.
Syntax
configure-user count number
undo configure-user count
Views
System view
Default command level
2: System level
Parameters
number: Specifies the maximum number of concurrent users.
The following matrix shows the value range for the number argument on different firewalls and firewall
modules:
Hardware Value ran
g
e
F1000-A-EI/F1000-S-EI 1 to 54
F1000-E 1 to 55
F5000 1 to 55
F5000-S/F5000-C 1 to 55
VPN firewall modules 1 to 55
20-Gbps VPN firewall modules 1 to 55