HP VPN Firewall Appliances Getting Started Command Reference

68
Parameters
slot slot-number: See the usage guidelines for this command.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see the chapter on CLI in Getting Started Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Usage guidelines
This command displays temperature information for all sensors.
The following matrix shows the value range for the slot-number argument on different firewalls and
firewall modules:
Hardware Value ran
g
e
F1000-A-EI/F1000-S-EI 0, indicates the PCB.
F1000-E 0, indicates the PCB.
F5000 0, indicates the MPU.
F5000-S/F5000-C 0, indicates the PCB.
VPN firewall modules 0, indicates the firewall module itself.
20-Gbps VPN firewall modules 0, indicates the firewall module itself.
Examples
# Display temperature information.
<Sysname> display environment
System temperature information (degree centigrade):
-----------------------------------------------------------------------------
Sensor Temperature LowerLimit Warning-UpperLimit Alarm-UpperLimit Shutdown-U
pperLimit
hotspot 1 33 0 60 70 NA
hotspot 2 57 0 80 92 NA
Table 11 Command output
Field Descri
p
tion
Temperature Current temperature.
LowerLimit Lower temperature threshold.
Warning-UpperLimit Warning temperature threshold.
Alarm-UpperLimit Alarming temperature threshold.
Shutdown-U
Shut-down temperature threshold. When the sensor temperature reaches
this limit, the system shuts down automatically.