HP VPN Firewall Appliances Getting Started Command Reference

82
Field Remarks
Wavelength unlocked
Wavelength of optical signal exceeds the manufacturer's
tolerance.
Temp high Temperature is high.
Temp low Temperature is low.
Voltage high Voltage is high.
Voltage low Voltage is low.
Transceiver info I/O error Transceiver information read and write error.
Transceiver info checksum error Transceiver information checksum error.
Transceiver type and port configuration
mismatch
Transceiver type does not match port configuration.
Transceiver type not supported by port
hardware
Transceiver type is not supported on the port.
Examples
# Display the alarms present on the transceiver module in interface GigabitEthernet 0/1.
<Sysname> display transceiver alarm interface gigabitethernet 0/1
GigabitEthernet0/1 transceiver current alarm information:
RX loss of signal
RX power low
Table 17 Command output
Field Descri
p
tion
transceiver current alarm information Alarms present on the transceiver module.
RX loss of signal Incoming (RX) signal is lost.
RX power low Incoming (RX) power level is low.
display transceiver diagnosis
Use display transceiver diagnosis to display the measured values of the digital diagnosis parameters for
transceiver modules.
Syntax
display transceiver diagnosis interface [ interface-type interface-number ] [ | { begin | exclude | include }
regular-expression ]
Views
Any view
Default command level
2: System level
Parameters
interface [ interface-type interface-number ]: Displays the measured values of the digital diagnosis
parameters for the transceiver module in an interface. The interface-type interface-number argument