HP VPN Firewall Appliances High Availability Command Reference

90
Use undo reaction to delete the specified reaction entry.
Syntax
reaction item-number checked-element probe-duration threshold-type { accumulate
accumulate-occurrences | average | consecutive consecutive-occurrences } threshold-value
upper-threshold lower-threshold [ action-type { none | trap-only } ]
undo reaction item-number
Default
No reaction entry for monitoring the probe duration is configured.
Views
DHCP operation view, DLSw operation view, DNS operation view, FTP operation view, HTTP operation
view, ICMP echo operation view, SNMP operation view, TCP operation view, UDP echo operation view
Default command level
2: System level
Parameters
item-number: Specifies a reaction entry ID in the range of 1 to 10.
threshold-type: Specifies a threshold type.
accumulate accumulate-occurrences: Specifies the maximum number of threshold violations, in the range
of 1 to 15.
average: Specifies to check the average operation duration.
consecutive consecutive-occurrences: Specifies the number of consecutive threshold violations after the
NQA operation starts, in the range of 1 to 16.
threshold-value: Specifies threshold values in milliseconds.
upper-threshold: Specifies the upper threshold in the range of 0 to 3600000.
lower-threshold: Specifies the lower threshold in the range of 0 to 3600000. It must not be greater than
the upper threshold.
action-type: Specifies what action to be triggered. The default action is none.
none: Specifies the action of only displaying results on the terminal display.
trap-only: Specifies the action of displaying results on the terminal display and meanwhile sending
SNMP trap messages to the NMS. This keyword is not supported for the DNS operation.
Usage guidelines
Only successful operations are monitored. Failed operations are not counted.
Examples
# Create reaction entry 1 for monitoring the average duration of ICMP echo operation. Set the upper
threshold to 50 milliseconds and lower threshold to 5 milliseconds. Before the NQA operation starts, the
initial state of the reaction entry is invalid. After the operation, the average probe duration is checked. If
it exceeds the upper threshold, the state is set to over-threshold. If it is below the lower threshold, the state
of the reaction entry is set to below-threshold. Once the state of the reaction entry changes, a trap
message is generated and sent to the NMS.
<Sysname> system-view
[Sysname] nqa entry admin test