HP VPN Firewall Appliances System Management and Maintenance Command Reference

100
undo info-center monitor channel
Default
The system outputs information to the monitor through channel 1.
Views
System view
Default command level
2: System level
Parameters
channel-number: Specifies a channel by its number in the range of 0 to 9.
channel-name: Specifies a channel by its name, a default name or a self-defined name. For information
about configuring a channel name, see info-center channel name.
Usage guidelines
The info-center monitor channel command takes effect only after the information center enabled with the
info-center enable command.
Examples
# Output system information to the monitor through channel 0.
<Sysname> system-view
[Sysname] info-center monitor channel 0
info-center security-logfile alarm-threshold
Use info-center security-logfile alarm-threshold to set the alarm threshold for security log file usage.
Use undo info-center security-logfile alarm-threshold to restore the default.
Syntax
info-center security-logfile alarm-threshold usage
undo info-center security-logfile alarm-threshold
Default
The alarm threshold for security log file usage is 80. That is, when the usage of the security log file
reaches 80%, the system outputs a message to inform the administrator.
Views
System view
Default command level
2: System level
Parameters
usage: Specifies an alarm threshold in the range of 1 to 100.
Usage guidelines
When the size of the security log file reaches the upper limit, the system deletes the oldest information
and then writes the new information into the security log file buffer. This feature can avoid security log
loss by setting an alarm threshold. When the threshold is reached, the system outputs log information to