HP VPN Firewall Appliances System Management and Maintenance Command Reference
148
Views
Any view
Default command level
1: Monitor level
Parameters
entry-number: Specifies a private alarm entry index in the range of 1 to 65535. If no entry is specified,
the configuration of all private alarm entries is displayed.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Getting Started Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Examples
# Display the configuration of all private alarm entries.
<Sysname> display rmon prialarm
PrialarmEntry 1 owned by user1 is VALID.
Samples type : absolute
Variable formula : (.1.3.6.1.2.1.16.1.1.1.6.1*100/.1.3.6.1.2.1.16.1.1.1.5.1)
Description : ifUtilization.GigabitEthernet0/1
Sampling interval : 10(sec)
Rising threshold : 80(linked with event 1)
Falling threshold : 5(linked with event 2)
When startup enables : risingOrFallingAlarm
This entry will exist : forever
Latest value : 85
Table 32 Command output
Field Descri
p
tion
PrialarmEntry Private alarm table entry.
owned by Entry owner, user1 in this example.
VALID
Entry status:
• VALID—The entry is valid.
• UNDERCREATION—The entry is invalid.
The display rmon command can display invalid entries, but the display
current-configuration and display this commands do not display their
settings.
Samples type Sampling type, whose value can be absolute or delta.
Description Description of the private alarm entry.
Sampling interval
Sampling interval, in seconds. The system performs absolute sample or
delta sample to sampling variables according to the sampling interval.