HP VPN Firewall Appliances System Management and Maintenance Command Reference
149
Field Descri
p
tion
Rising threshold
Alarm rising threshold. An event is triggered when the sampled value is
greater than or equal to this threshold.
Falling threshold
Alarm falling threshold. An event is triggered when the sampled value is
less than or equal to this threshold.
linked with event Event index associated with the private alarm.
When startup enables How can an alarm be triggered.
This entry will exist Lifetime of the entry, which can be forever or span the specified period.
Latest value Count result of the last sample.
Related commands
rmon prialarm
display rmon statistics
Use display rmon statistics to display RMON statistics.
Syntax
display rmon statistics [ interface-type interface-number ] [ | { begin | exclude | include }
regular-expression ]
Views
Any view
Default command level
1: Monitor level
Parameters
interface-type interface-number: Specifies an interface by its type and number.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Getting Started Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Usage guidelines
This command displays the interface statistics during the period from the time the statistics entry is created
to the time the command is executed. The statistics are cleared when the device reboots.
Examples
# Display RMON statistics for GigabitEthernet 0/1.
<Sysname> display rmon statistics gigabitethernet 0/1
EtherStatsEntry 1 owned by null is VALID.
Interface : GigabitEthernet0/1<ifIndex.3>
etherStatsOctets : 43393306 , etherStatsPkts : 619825