HP VPN Firewall Module Series - HP SECBLADEIII-CMW520-R3819 Release Notes
37
|1 6819 Feb/03/2012 10:39:24 N/A cfa0:/system.xml |
|2 207865 Dec/07/2011 17:43:38 N/A cfa0:/logfile/~/logfile.log |
|3 1271 Feb/03/2012 10:39:26 M+B cfa0:/startup.cfg |
|4 19790016 Feb/02/2012 11:01:50 M cfa0:/main.bin |
|0 Exit |
============================================================================
Enter file No:
2. Enter the number of the file you want to delete and press Enter.
3. When the following prompt appears, enter Y.
The file you selected is cfa0:/logfile/~/logfile.log,Delete it? [Y/N]Y
Deleting..............Done!
Handling software upgrade failures
If a software upgrade fails, the system runs the old software version. To handle a software failure:
1. Check the physical ports for a loose or incorrect connection, and verify that the LEDs are
reflecting the correct port status.
2. If you are using the console port for file transfer, check the HyperTerminal settings (including
the baud rate and data bits) for any wrong setting.
3. Check the file transfer settings:
If XMODEM is used, you must set the same baud rate for the terminal as for the console
port.
If TFTP is used, you must enter the same server IP addresses, file name, and working
directory as those set on the TFTP server.
If FTP is used, you must enter the same FTP server IP address, source file name, working
directory, and FTP username and password as those set on the FTP server.
4. Check the FTP or TFTP server for incorrect settings.
5. Check that the CF card has enough space for the upgrade file.
6. If the message "Something is wrong with the file" appears, check the file for file corruption.