HP VPN Firewall Module Series - HP SECBLADEIII-CMW520-R3819P05 Release Notes
26
Table 12 Serial submenu options
Item
Description
<1> Download Application Program To
SDRAM And Run
Download a system software image to the
SDRAM through the serial port and run the
image.
This option is available only if password
recovery capability is enabled.
<2> Update Main Application File
Upgrade the main system software image.
<3> Update Backup Application File
Upgrade the backup system software image.
<4> Update Secure Application File
Upgrade the secure system software image.
<5> Modify Serial Interface Parameter
Modify serial port parameters.
<0> Exit To Main Menu
Return to the EXTEND-BOOTWARE menu.
2. Enter 5 in the Serial submenu to change the baud rate of the serial port.
If you use the baud rate of 9600 bps, skip this step and go to step 10.
Make sure the terminal and the serial port use the same baud rate.
===============================<BAUDRATE SET>===============================
|Note:'*'indicates the current baudrate |
| Change The HyperTerminal's Baudrate Accordingly |
|---------------------------<Baudrate Available>---------------------------|
|<1> 9600(Default)* |
|<2> 19200 |
|<3> 38400 |
|<4> 57600 |
|<5> 115200 |
|<0> Exit |
============================================================================
Enter your choice(0-5):
3. Enter an appropriate baud rate option. For example, enter 5 to select 115200 bps.
Baudrate has been changed to 115200 bps.
Please change the terminal's baudrate to 115200 bps, press ENTER when ready.
NOTE:
The size of a .bin file is typically over 10 MB. Even at 115200 bps, the download
takes about 30 minutes.
4. Select Call > Disconnect in the HyperTerminal window to disconnect the terminal from
the firewall module.
Figure 3 Disconnecting the terminal
5. Select File > Properties, and in the Properties dialog box, click Configure.