Installation and Getting Started Guide for 745wl and ACM xl 2006-06

2-6 ProCurve Secure Access 700wl Series Installation and Getting Started Guide
Hardware Installation
Installing a 700wl Series System
Unpacking
Carefully unpack the contents of the shipping containers, and save the containers and all packing
materials. To save storage space, you may want to flatten the containers. Check that the following is
included:
•Chassis
Hardware and Accessories Kit
12-24 x 5/8 inch Phillips pan-head bolts, zinc (quantity: 4)
10-32 x 5/8 Phillips washer-head bolts, black (quantity: 4)
Mounting Slide Kit
—U.S. power cord
AT null modem cable (DB-9 female/DB-9 female)
Documentation Kit
Documentation CD-ROM
Software License Agreement
Software Release Notes
ProCurve Secure Access 700wl Series Installation and Getting Started Guide (this document)
If any of the above are missing, contact HP immediately and do not attempt installation.
Rack Mounting the Chassis
Each Access Control Server 745wl comes with a steel mounting kit suitable for mounting the chassis in a
standard 19-inch (48.3 cm) equipment rack. Rack mounting instructions are included in the kit.
Table 2-3. Site Power Requirements, Temperature and Heat Dissipation Parameters
Parameter Value
AC Input Power (Watts) 170
Heat Dissipation (BTU/Hr.) 580
AC Input Current at 120 VAC (Amps) 1.4
AC Input Current at 240 VAC (Amps) .70
Operating Temperature Range,
×
C 5 to +50
°
C
Storage Temperature Range,
×
C -40 to +65
°
C
Humidity Range, non-condensing, percent 5 to 90