Installation and Getting Started Guide, ONE Advanced Services zl Module 2010-03
1-5
Hardware Installation
Environmental Specifications
Environmental Specifications
Temperature Operating
0C to 45C (32F to 113F)
a
a. A maximum of 4 of these modules may be installed in any zl switch
(except the 8206zl chassis, which supports a maximum of 2 of
these modules). If a module is installed in excess of these quanti-
ties, the module will not boot.
For the 5400zl chassis, if all modules are installed in the left hand
side of the chassis the temperature specification is set to 50°C for
the chassis. If any modules are installed on the right hand side of
the chassis, then the temperature specification for the chassis is
40°C.
If you are running a 5406zl and want the 50°C temperature speci-
fication, then only three modules are supported in the chassis as
that is all the slots there are on the left hand side.
For the 8200zl chassis, if all modules are installed in the left hand
side of the chassis the temperature specification is set to 45°C. If
any modules are installed on the right hand side of the chassis,
then the temperature specification for the chassis is 40°C.
Non-Operating
-10C to 65C (-10F to 149F)
Relative humidity
(non-condensing)
15% to 90% at 40C (104F) 15% to 90% at 65C (149F)
Maximum altitude 3.0 km (10,000 ft) 4.6 km (15,000 ft)