Management and Configuration Guide (Includes ACM xl) 2005-12

A-12 ProCurve Secure Access 700wl Series Management and Configuration Guide
set uplink [<slot>/<port>]
Sets the network uplink port to the specified port or slot and port. <slot>/<port> specifies the port
on a Gigabit Ethernet option card. For a single-port card, the port number is 1.
There is a delay of several seconds before the port switch takes effect.
To reset the uplink port to the default network uplink port, enter the
set uplink command without
a port specification, or use the following port specifications:
0/2 (slot 0 port 2) for a 700wl Series unit
Caution:
Disconnect the system from the network before you issue this command. As soon as you
reconfigure the uplink port, the port that was functioning as the uplink port prior to the
reconfiguration becomes a downlink port. If it remains connected to your network, serious problems
can occur.
Note: You will need to reboot your system for uplink changes to take effect.
show uplink
Shows the current uplink port. Output from this command is similar to the following:
The uplink is configured at: Slot 0 Port 1
set portmedia {<port> | <slot>/<port>} "<media> [<media-option>]"
Sets the port media setting for the specified port or slot and port.
You can use the
show portmedia command to get a list of supported media and media option
settings.
show portmedia <port> | <slot>/<port>
Shows the port media settings for the specified port or slot and port.
For example, the command:
show portmedia 3/1
<port> | <slot>/<port> The port, or slot and port on which to set the media type and option.
<media> The media type, for example 100baseTX or 10baseT/UTP. Must match one
of the valid media types for the port, as displayed in the show portmedia
command for the port.
<media-option> A media option, for example full-duplex. This is not required.
If used, the media plus media-option specification (within the quotes) must
match one of the valid settings for the port as displayed by the show portmedia
command for the port.