Release notes - H3C SecBladeII-CMW520-F3169P07

35
Field Description
Local IP Address IP address of the interface connecting the TFTP server
Gateway IP Address
IP address of the gateway. You do not need to configure
it.
FTP User Name
FTP username, which will be used for FTP downloading,
but not for TFTP downloading.
FTP User Password
FTP password, which will be used for FTP downloading,
but not for TFTP downloading.
l To use the default parameter after a colon, press Enter directly.
l If the Ethernet port parameter settings fail to pass CRC check, the system adopts the default
settings and displays Check net params crc error, use the default value.
3) After the above configurations, you will return to the Ethernet submenu, where you can select 2
to upgrade the main application file.
Loading................................... done
10129712 bytes downloaded!
Updating File cfa0:/main.bin
.........
Update Success!
l If the application file name you entered already exists on the CF card, The file exists, will you
overwrite it? [Y/N] will be prompted. If you enter Y, the application file on the CF card will be
directly overwritten. The upgraded application file will become the only main application file.
l Make sure that the available space on the CF card is enough. Otherwise, The free space isnt
enough will be prompted.
l If you want the SecBlade card to use the downloaded file, you need to specify the file for the next
boot. For related information, refer to Specifying Files on page 14.
4) After the main application file is upgraded, select 0 to return to the main menu, where you can
select 1 on the main menu to reboot the SecBlade card from the CF card.
Upgrading Application Files Using TFTP at the CLI
1) Set up an upgrade environment.
Connect the PC to an Ethernet interface (for example, GigabitEthernet 0/1) on a SecBlade and
ensure the connectivity between them.
l The SecBlade card serves as the TFTP client while the PC serves as the TFTP server.