Riverbed® Steelhead® RiOS® Application Installation and Getting Started Guide 2010-10
Table Of Contents
- 1: Overview
- 2: Hardware Installation
- 3: Getting Started
- Initial Configuration
- Configure the Steelhead Application
- A: EMC Regulatory Statements
- B: Waste Electrical and Electronic Equipment (WEEE) Statements
- C: Hardware Components
- D: Software Components

3-29
Getting Started
Configure the Steelhead Application
8. Check your configuration settings:
amnesiac (config)# show in-path
Enabled: yes
Kickoff: no
Maintain Multipath: no
Main Interface: inpath0_0
Asymmetric Routing Detection: yes
Asymmetric Routing Pass Through: yes
Optimizations Enabled On:
inpath0_0
VLAN Tag IDs:
inpath0_0: 1
9. View additional information with the show procurve all command.
amnesiac(config) # show procurve all
Hardware Information
Blade Serial: SG99900000
Switch IP: 10.28.244.222
Chassis Name: ProCurve Switch 5406zl
Slot: C
Riverbed Serial: H77K00000000
Switch System MAC: 00:21:f7:b8:a9:00
Configuration Notifications:
No Configuration Notifications
10. Enter the show report system hp_hardware and the show report system
hp_software commands to view information about the hardware and
software.
amnesiac (config) # show report system hp_hardware
hp_hardware
------------------------------
status: OK
info: Blade Serial-SG9999Q999 Switch IP=13.28.22.227
Chassis Name-ProCurve
Switch 5406zl. Slot-C Riverbed Serial-H77KX00000000
amnesiac (config) # show report system hp_software
hp_software
-------------------------------
status: OK