TMS zl Management and Configuration Guide ST.1.1.100430
2-89
Initial Setup in Routing Mode
Configure SNMP Settings
■ Firewall, including NAT and port triggers as well as access policies
■ IDS/IPS operations
With NIM, you can also view TMS zl Module logs.
To enable management through PCM+/NIM, you must first configure a few
settings on the TMS zl Module:
1. Associate the PCM+/NIM server’s VLAN with a zone, preferably a manage-
ment-access zone. (“Plan the Zones” on page 2-8.)
2. If the PCM+ server is not in a management-access zone, configure firewall
access policies to permit at least ICMP/Echo, SNMP, SNMP traps, Telnet,
SSH, and HTTPS traffic to the PCM+ server.
You should also create any other policies that PCM+ and the TMS zl
Module will need to communicate. The necessary policies depend on how
you are using the devices on your network.
3. Configure SNMPv1/2c with the PCM+ server’s community names or
SNMPv3 with the user settings configured on PCM+.
For more information about managing the TMS zl Module through PCM+/NIM,
see the HP ProCurve Manager Network Administrator’s Guide, version 3.10
or later.
Note In addition to managing the TMS zl Module with PCM+/NIM, you can integrate
the module’s IDS/IPS functions with the threat management solution con-
trolled by NIM. See “Managing the TMS zl Module with HP Network Immunity
Manager” on page 6-37 of Chapter 6: “Intrusion Detection and Prevention.”